Sequencing batch reactors

Consistent sample-based checks for SBR operating routines.

PMA colleagues working at a wastewater-treatment facility

A defined role in your monitoring routine.

The S3A supports routine comparison of mixed-liquor concentration and settlement behaviour in sequencing batch reactor applications, where a representative sample falls within the instrument specification.

Record the operating context and the point in the site’s sampling routine with each result. Samples collected under different process conditions should not be treated as interchangeable observations.

From a representative sample to a recorded result.

Prepare the sample

Collect a representative sample using the site’s procedure. Use a 210 ml sample and confirm that the expected MLSS is within the specified 50–6,500 mg/L range. Readings above 6,500 mg/L are indicated as INF.

Run the test

S3A provides an MLSS result in approximately 10 seconds, followed by a 30-minute unattended settlement cycle. Standard outputs include SVI, settled sludge level, supernatant clarity and floating sludge.

Review in context

Review completed measurements alongside the sample identity and site observations. Store up to 28 completed results for each of three internal locations, with date and time.

Record the process context

Discuss the representative sampling point and operating context with the site team. S3A does not control the reactor or replace its operating procedures.

Calibration and optional measurements

Calibrate with a site-specific sample of known MLSS between 2,000 and 4,000 mg/L. Repeat after large changes in sludge characteristics. SSVI and SSSL require the optional stirrer module.

Optional connection to a client system.

Specify optional MODBUS RTU over two-wire RS-485 when ordering. Read functions 03/04 provide supported readings to a compatible client system; dashboards and integration are client-provided. Function 06 is limited to Holding Register 40001 for the slave ID (1–247), not measurement writes or test control.

Operational measurement, not a replacement for required laboratory analysis.

S3A supports operational checks of activated sludge. Required compliance sampling, regulatory testing and laboratory analysis must still follow the procedures that apply to the site.

Operate indoors in a safe area at 0–45°C, in noncondensing conditions and away from direct and reflected sunlight. Follow the current manual and the treatment works’ safety and sampling procedures.

Continue your application review.

Measurement parameters

Explore the S3A measurement parameters for activated sludge, including MLSS, SVI, settled sludge level, supernatant clarity and floating sludge.

Explore guide

S3A product details

Explore the portable S3A suspended solids and MLSS analyser for activated sludge: 210 ml sample, rapid MLSS result and 30-minute settlement cycle.

Explore guide

Contact PMA

Contact PMA UK to discuss S3A applications, product information, demonstrations, technical support, calibration and wastewater settlement testing.

Explore guide

Bring your process into focus.

Discuss your S3A application, measurements and operating requirements with PMA.